All guides

Help Center · SpectraSense

Level (beta) — estimated levels, rules and the level log

Level is in beta — readings aren't reliable yet while the calibration is reworked, so they are not for limits. Estimated levels with the live spectrum, rings still marked; your own meters (Fast / Slow, max, Leq, peak, crest, C − A), audience rules as a guide, a scheduled level log you can export (marked Beta), and Show mode for FOH.

Open SpectraSense

On this page
  1. The live spectrum next to the meters
  2. Not calibrated: estimated dB SPL
  3. The meters
  4. Show mode — Level fullscreen for FOH
  5. How the mic curve is applied
  6. Rule
  7. Sent vs heard
  8. The log
  9. Saved logs stay on this device
  10. Good to know

Beta

Readings aren't reliable yet: calibration is being reworked. Not for limits. Level shows estimated levels next to the live spectrum — a guide while you work, not a meter reading you can rely on, not a record and not a compliance check. Ringing out is what SpectraSense is for; see Ring out.

The Level view shows levels from the mic channel you picked in Settings, with the live spectrum right there. Tap Start — on the status bar, or on an upright phone in the action bar at the bottom — and it reads at once. On an upright phone the action bar also holds Start log / Stop log.

The live spectrum next to the meters

On a computer the spectrum takes the full width and the meters sit in one compact row under it: the main meter, the other meters, then Show mode and Meters. Meters: Below | Above | Sidebar in the toolbar moves that row over the spectrum, or back into a column to its right; SpectraSense remembers the choice and syncs it with your account. The switch is there on a wide screen; a tablet always has the row, and a phone a short spectrum strip above the big number. It is the same spectrum as Ring out, with the same detector: a ring is marked on it and labeled with its cut — 2,340 Hz · pull 2.5k −3 dB — so a ring that starts while you watch the levels shows without switching views, and it still lands in the Rings list.

The toolbar over the spectrum:

  • 1/3 oct | Line — fractional-octave bars (1/3 octave by default) or the FFT line. The band width itself is set in Spectrum options; the button shows it, e.g. 1/6 oct.
  • Freeze and Hold, as on Ring out.
  • Meters: Below | Above | Sidebar — where the meters sit (wide screens).
  • Options opens Spectrum options beside the spectrum (see Ring out). Ring out and Level share one look; Level keeps only its own bars/line choice.

Not calibrated: estimated dB SPL

The meters always read dB SPL — dB(A), dB(C), dB(Z) — so a threshold of 99 means 99 decibels. Until that input and channel have a level offset they are estimated: the numbers look the same, with a small est. beside the unit. The estimate is the one from a UMIK's name (Estimate in Settings), otherwise the common default 0 dB FS = 140 dB SPL — a convention, not a measurement: depending on the mic and its input gain it can be 10–30 dB off. Thresholds and the rule work on the estimate too: a meter turns red above its threshold, and the rule's verdict ends in (est.).

Level shows one short line, Estimated levels — calibrate for exact numbers., with a Calibrate button: it opens Settings at the Level offset — a calibrator, a reference meter, or Known value if another measurement app or an earlier calibration gave you the number (see Calibrating the mic). The status bar says Estimated · Calibrate whenever there is no level offset — even with a mic curve loaded, because a mic curve corrects the shape, not the level.

Once calibrated, the line and every est. are gone and the status bar says Calibrated. A level offset belongs to one input and one channel — and, when a mic from My mics sits on it, it is kept with that mic too, so another browser with the same mic is calibrated as well.

The meters

Every number in this view is a meter — the main one is simply the first meter, shown big. Out of the box you get the country rule's set (the factory meters), following the Rule you picked:

  • DIN 15905-5: LAeq 10 s as the main meter, the LAeq of the running 30-min block (it shows a value from the block's first second, not only at its end) and LCpeak max — thresholds 99 and 135, the figures of the standard.
  • Other rules the same shape from their own window and figures: LAeq 10 s as the main meter, LAeq over the rule's window, LCeq for a C limit (France), LCpeak max, LAFmax for a Fast-max ceiling (Switzerland).

Tap a meter's name to choose what it measures, the way a measurement app's numeric meter is set:

  • Value
    • Level (RMS) — the level now, Fast (125 ms) or Slow (1 s): LAF, LAS, LCF, LZS…
    • Maximum — the loudest Fast or Slow reading since the reset: LAFmax, LASmax…
    • Leq — the energy average over the rule's window, 10 s, 1, 5, 10, 15, 30 or 60 min, or since the reset: LAeq 30 min, LCeq 15 min…
    • Peak — the highest sample in the last second, or since the reset (LCpeak max, LZpeak…).
    • Crest factor — peak minus the Leq of the last second, in dB: how spiky the signal is.
    • C − A — over the last minute. Above 10 dB the low end carries the level — the bass is what to look at for a C limit or the neighbors.
    • Rule reading — the rule's own reading: its window (DIN: this block) or its second number (the block's projection, the LCeq, the loudest window).
    • Verdict — the rule's verdict in words: under or over the limit, or why it cannot judge yet.
    • Gain — the mic minus the master (both unweighted, Slow), in dB: how much louder the room is than what the console sends. Needs the master channel in Settings.
    • Delay — Tune's live delay estimate, in ms, while it measures (it goes on in the background).
  • Weighting — A, C or Z (unweighted, flat), per IEC 61672. These are sound levels, not LUFS: LUFS is a broadcast loudness measure (K-weighted) and has no place in an audience-rule report — RoomSense has a LUFS meter if you need one.
  • Threshold (optional) — the meter turns red above it, in its own unit: type 99 for 99 dB SPL. It works on estimated levels too (est.).

Edit, presets, your default

The Meters menu, under the meters next to Show mode, holds it all:

  • + Add meter adds one (up to 12); with no main meter, the new one becomes the main one.
  • Edit meters puts on every meter: × to remove it (the main one too), Make main to make it the main meter (the main one takes its place) and ‹ › to move it, with a hint line on how. Done editing puts the tiles back to clean.
  • Presets: No meters (just + Add meter), Country rule: … (the factory meters above, named after your rule) and Just SPL (LAS as the main meter, and LAFmax).
  • Save as my default keeps the set on screen as yours — synced with your account when you are signed in, so a new browser starts with it. My default meters returns to it after you tried something else.
  • Reset readings starts every "since the reset" value over; the windows keep up to the last hour.

Your working set stays on this device. If you still had the long set from an older version, Level asks once: Start over? — No meters, Country rule or Keep.

Under the meters:

  • Clipping: when the input reaches full scale Level says so, and which channel. Readings are too low while it clips — turn the input gain down; Check level opens Settings → Input level. Low input is said the same way. A trim set there never moves these readings: the levels are read before the trim, where the level offset belongs.
  • Bass: above 10 dB of C − A Level says the low end carries the level.

Another mic channel or another input starts the meter over.

Show mode — Level fullscreen for FOH

Show mode, next to the meters, puts Level alone on the screen for front of house: the spectrum, the same meters as Level (there is no second set), the clock, the rule's reading and verdict, and the log line with its Start log / Stop log button. Exit show mode (or Esc) returns. The input keeps running, and the screen is kept on while listening. Show mode hides the phone's tab bar and action bar. An iPhone has no fullscreen for a page: Show mode then covers the page instead. An old #show link opens Level.

How the mic curve is applied

The A and C weighting run on the signal as the mic delivers it. When a mic curve is loaded, the mic channel first passes a filter whose response is the curve's correction (a 4,096-tap linear-phase FIR), so every band is corrected before it is weighted — not one number for the whole band. The correction is taken relative to 1 kHz, because a level offset set with a calibrator already holds the mic's level at 1 kHz; corrections are limited to ±20 dB. After a calibration against a reference meter with pink noise the broadband level can differ by a fraction of a dB from the meter's, as the curve then corrects the noise's other bands too.

Rule

Pick the Rule: DIN 15905-5 (Germany), V-NISSG (Switzerland), the WHO standard, the Dutch covenant, the French decree, VLAREM (Flanders) or the UK HSE guidance. The default follows your language (German → DIN, French → the decree, Dutch → the covenant, otherwise WHO). Level shows the rule's window and limit and reads the level the way the rule does:

  • DIN 15905-5: LAeq over 30-minute blocks from :00 and :30, and what the running block ends at if the level stays.
  • V-NISSG: every 60-minute window, and the loudest one so far.
  • WHO, NL, FR, VLAREM: a moving window (15 or 60 minutes); for France the C-weighted Leq limit beside it.
  • UK: the whole event.

The Rule picker sits in the rule & log strip under the spectrum and the meters, with its verdict next to it — 0.9 dB below the limit., and 0.9 dB below the limit. (est.) while not calibrated.

LCpeak and LAFmax ceilings are checked where the rule has one. The rule's readings and its verdict are meters (Value → Rule reading / Verdict), so you choose whether they are on screen. While a log runs the limit is judged on the log; otherwise on the live meter. The readouts stay neutral until a value is actually over — a limit is not a target. Rules are as of the date shown; this is not legal advice — Read the rule links the legal text. While Level is in beta, a verdict is a guide only: the readings behind it are not reliable yet, so it never shows that a show kept a limit.

Sent vs heard

While the test tone plays (Settings), a small Test tone: sent vs heard box shows what is sent (the tone's RMS in dB FS), what is heard (the C-weighted Fast level at the mic) and the difference — the gain from the output to this place. Heard reads dB SPL (est. until the channel is calibrated). The box is gone when the tone stops.

The log

Rule and log are one strip under the spectrum and the meters: the Rule picker with its verdict, then Log schedule, Correction, Start log (Stop log while it runs) and Report. Log schedule, Correction and Report are folds — one is open at a time.

The log is three things: a schedule that logs by itself, the report details (filled in before the start, in the Report fold), and the export afterward — PDF, print sheet and CSV. While Level is in beta every export says so on top: Beta — readings aren't reliable yet: calibration is being reworked. Not a valid report, not for limits.

Log schedule — one sentence

Log every 5 min from 19:00 to 23:30 on today. The sentence is in the Log schedule fold:

  • Log every 1 s, 10 s, 1, 2, 3, 5, 10, 15, 30 or 60 min (5 min by default, as DIN 15905-5 and V-NISSG records). Rows of a minute or more start on the clock (:00, :05…; 3 min: :00, :03…).
  • from / to — both optional. To 01:30 after a start at 22:00 runs over midnight. on: today, tomorrow or a date. Scheduled at 20:10 for 19:00–23:30, the log starts at once and stops at 23:30.
  • Values: LAeq, LCeq, LZeq, LAFmax, LASmax, LCpeak, LZpeak.

With a start time the button reads Start at 19:00, with Start now beside it. Scheduled, the line under it says Scheduled — starts 19:00 (in 1:12:04). Keep this tab open.; while it logs, Logging since 19:00 and Stops by itself 23:30. Cancel schedule drops the waiting start. Press Start first: Start log, Start at 19:00 and the correction's Measure 5 s never turn the input on by themselves — while it is off they say Start first. Pressing Stop while a log runs asks first; a second tap stops the log too.

Honest limit: a schedule runs only while this tab stays open with the input started — there is no background logging on the web. Keep the computer awake and plugged in (SpectraSense keeps the screen on where the browser allows). If the page is reloaded, the schedule is kept, but a browser needs a tap before audio can start again: a bar on every view asks you to tap Continue to keep logging 19:00–23:30. If the reload cut a running log, Continue goes on with the same log (the reload shows as a gap); Not now lets the schedule go.

Before the start: report details

Report details · 6 of 11 (in the Report fold) holds the details a level record usually names: organizer, who writes the report (Report by), event, venue, PA type and layout, the audience position (the loudest audience spot), the mic position (where the mic is, e.g. FOH), measuring device, calibrator, calibration result and sound engineer. The fields the chosen rule needs are marked with *; nothing blocks a start. The details carry over from the last log, and when you open the box the measuring device (your mic from My mics on the input) and the calibration result are offered from the open input.

Correction — when the mic is not where the audience is

The mic stays at the mic position (FOH — the standard's substitute position), but the rule judges the loudest audience spot, the audience position (the standard's assessment position). The Correction fold finds the difference — DIN 15905-5 calls the two values K1 and K2: play pink noise through the PA (Test tone (pink) uses the test tone — set its level in Settings → Test tone — or use pink noise from the desk), Measure 5 s with the mic at the mic position, then take the mic to the audience position and Measure 5 s again. Correction A (dB) (K1) comes from LAeq, Correction C (dB) (K2) from LCeq. Or type them with a line on how they were found. The report adds Correction A to the A-weighted levels (LAeq, LAFmax, LASmax — so the periods read LAr) and Correction C to LCeq and LCpeak; the corrections and their method are printed. No correction removes them.

During the show: event notes

While logging, Event notes appear under the strip: Changeover, Act starts (with the name typed in the line, Band 2 starts) and Add note stamp the time. The notes are numbered on the PDF's chart, listed in the PDF and the print sheet, and written into the CSV. × removes one.

Stop, and the report

  • Every stop saves the log — by hand, by the schedule's stop time, or a page closed while logging (saved on the next visit). The log keeps the calibration that was in force when it started. A log taken without a level offset reads estimated dB SPL like the meters: its report says Level offset +140.0 dB (estimated), the units carry est. (the CSV's columns end in dB(A)est), and the sheet says Estimated levels (not calibrated) — not a valid report.
  • Apply calibration (in the Report, and on the log's row in Saved) reads a log again with another level offset: leave the field empty for this input's calibration now, or type a level offset. Every value of the log moves with it, and the report then says Level offset +114.0 dB (calibrated …) · applied later …. It is right only with the same mic and the same input gain as during the log. Undo puts the earlier numbers back. A log saved in dB FS by an earlier version opens with the estimate and est., ready for Apply calibration.
  • The Report fold holds the rule's text with Read the rule, the report details and the readings: the rule's Periods (DIN: 30-minute blocks with their LAeq against the limit) and the rows at your interval (the newest 120 on screen). Because every second is kept, the interval and the values can be changed after the show.
  • PDF — an A4 level report, with the Beta line on top: the details, the rule, how the levels were taken, the correction, the assessment with a verdict per period, the level over time with the limit lines and your notes, every row (a very long log at 1 s is summed to a coarser interval in the PDF — the CSV has every row), gaps, a signature line and the SHA-256 of the record on every page. It is made on this device; nothing is uploaded.
  • CSV — the same report for a spreadsheet: the Beta line, the details, the interval, the correction with its method, the notes and the hash on top, then one line per row with local time and each value, its unit in the column name.
  • Print (A4) stays as the fallback (and is what Japanese, Korean and Chinese use, since the PDF has no font for those scripts — choose Save as PDF in the print dialog).
  • Changed after the stop, Save on this device replaces the saved copy.

A real meter's log can be the source instead: Import meter CSV takes a time column and an LAeq column (LCeq optional), separated by tabs, semicolons or commas, dates as 2026-10-03 or 03.10.2026. The correction applies to it too.

Saved logs stay on this device

All of this is in the Report fold. Save on this device (and every stop) keeps the log (record, hash and seconds) in this browser — never synced to your account, because a report names people and places. On a shared computer another account does not see them. Export file writes all Saved logs as one JSON file; Import file brings them back on any computer, and Open checks the SHA-256 again.

SpectraSense and RoomSense keep their logs in one store on this device: the list shows both, each marked with the tool that saved it, and a RoomSense log opens here (and a SpectraSense one in RoomSense) under the rule it was saved with.

Good to know

  • A phone or laptop mic is indicative: calibrate against a real meter and expect a few dB of error; built-in mics clip above about 115 dB SPL, so LCpeak from them means little. A mic curve may lift a frequency by at most 6 dB in the level chain (its cuts are kept whole): a laptop mic's own curve asked for +20 dB where the mic hears almost nothing, which turned a knock into a peak above 0 dB FS. For a record the law asks for, use a class 1 or class 2 meter and import its log (CSV).
  • LCpeak is the highest sample, not an analog true peak.

Was this page helpful?