All guides

Help Center · RoomSense

Room types — what each one adds

Live club, open air, hall / theater / conference, studio / control room, concert hall and cinema — the checks each room type adds, the standards behind them, how sure the figures are, and where the estimate ends.

Open RoomSense

On this page
  1. Source lines
  2. Live club / venue (default)
  3. Festival / open air
  4. Hall / theater / conference
  5. Studio / control room
  6. Concert hall
  7. Cinema
  8. Loudness targets

Pick the Room type at the top of Room plan (Edit room, or the type chip of the facts strip). It is saved with the room and changes which answers appear: the checks for that type join the answers in Room — some join System and Show too. The verdict picks up the type's main result.

Source lines

Every figure that comes from a standard carries a source line under its card:

  • checked against the published text — read in the standard or guideline itself (linked where it is free);
  • from published summaries — the standard itself not yet checked — the standard isn't freely available; the figures agree across several published summaries. Treat them as such.

Every room type gives figures to plan with — an estimate, not an assessment or a certificate. A measurement in the real room, and the authority or the standard's own text, decide.

Live club / venue (default)

  • Neighbors — bass through the wall (an answer in Room): the club's level in the 63 Hz and 125 Hz octaves, one wall (plasterboard, 115 or 240 mm brick, 200 mm concrete, or your own surface mass) and the level next door against the inside values for day (35 dB(A)) and night (25 dB(A)) of the LAI guideline 4.2 / TA Lärm. Textbook mass law R ≈ 20 lg(m′·f) − 47 dB: a single wall, no flanking paths.
  • Clarity vs distance and the STI estimate in Speech & music — as in the concert hall and hall types below.

Festival / open air

The room answers (bass & room modes, reverb, treatment) are left out — there are no walls.

  • Level at the neighbors: from the level at FOH, its distance from the PA, the distance to the nearest homes, the PA height and the window height, RoomSense estimates the level at the homes — distance, air (from the temperature and humidity in the Room plan) and ground, downwind, after a simplified ISO 9613-2 (from published summaries). Typically ±3 dB; no barriers or buildings in between.
  • Against the limits — pick the rule:
    • Germany — LAI Freizeitlärm-Richtlinie (2015) (checked): the area around the homes (commercial, mixed, general or purely residential, spa / hospital), working day or Sunday, regular or rare event (at most 18 days a year). The values for day 08–20, the rest periods 06–08 and 20–22, and the loudest full hour at night; enter Show ends at and RoomSense says which value your last hour is judged against. Rare events, single peaks and the inside values are listed. The Länder may differ — e.g. NRW.
    • UK — Noise Council code (1995) (checked): concert days a year — 1–3 days in an urban stadium or arena (75 dB(A)), 1–3 days elsewhere (65 dB(A)), or 4–12 days (the background LA90 + 15 dB) — as LAeq,15min at 1 m from the façade, 09:00–23:00. After 23:00 the music should be inaudible inside with the windows open. Low frequencies: up to 70 dB in the 63 or 125 Hz octave is satisfactory, 80 dB or more causes significant disturbance (informative).

Hall / theater / conference

Room targets holds the first three; the STI estimate sits in Speech & music.

  • Targets for halls and conference rooms — DIN 18041 (from published summaries): pick the group — A1 music, A2 speech / lecture, A3 teaching / communication, A4 teaching, inclusive, A5 sport. RoomSense gives the target for the volume and checks the occupied RT per octave against the tolerance band. Outside the group's volume range (A1 30–1 000 m³, A2 50–5 000, A3 30–5 000, A4 30–500, A5 200–30 000) it says no target instead of extrapolating. DIN 18041 judges the room about 80 % occupied — set the audience accordingly.
  • UK school rooms reference (BB93, 2015) (checked): the empty, furnished room's T_mf against BB93's rooms — assembly hall, drama studio, lecture rooms, performance room, meeting room — new build and refurbished.
  • Offices and conference rooms (ASR A3.7, Germany) (checked): the limits for offices and call centers, training rooms (occupied RT ± 20 %), the mean absorption asked for in rooms with speech, and the background-noise guide.
  • STI estimate (diffuse field) — not a measured IEC 60268-16 STI (figures from published summaries): from the occupied RT per octave, the speech level (at 1 m or at the listener) and the background noise, at five distances, with the voice-alarm guide (mean ≥ 0.50, lowest ≥ 0.45). No direct sound, echoes or masking.

Studio / control room

In Room — Control-room reverb, Size & proportions and Background noise:

  • Reverb time against the control-room mask: the empty room's estimated RT per octave against the tolerance mask around Tm = 0.25 (V / 100 m³)^⅓ from ITU-R BS.1116-3 and EBU Tech 3276 (checked), with the EBU guide range 0.2–0.4 s. The ⅓-octave step rule needs a ⅓-octave measurement — octave estimates cannot show it.
  • Size and proportions: floor area (EBU: at least 30 m² for a control room, 40 m² for a reference room; BS.1116: 20–60 m² stereo, 30–70 m² multichannel), volume (EBU: up to 300 m³), the ratio rule.
  • Background noise: NR 10 / NR 15 — enter octave-band levels from a measurement; a phone or laptop microphone's own noise is usually above NR 15.

In System — First reflections and Speaker layout:

  • First reflections and the front wall: the stereo triangle at 60° in the room — where the first reflections off the side walls, floor and ceiling hit, how late and how loud they arrive against "≥ 10 dB down within 15 ms", and the first cancellation from the wall behind the speakers.
  • Speaker layout: Stereo (2.0), 5.1 (ITU-R BS.775), 5.1.4 (BS.2051 System D), 7.1.4 (BS.2051 System J, Dolby studio rules) — each speaker's angle and position for a listening distance; a speaker the room cannot hold goes onto the wall, and the nearer ones get a delay and a level trim.

In Show — Reference listening level — and in Measure:

  • Reference listening level by standard — EBU Tech 3276 (85 − 10 lg n dB(A)), its Supplement 1 for multichannel, ITU-R BS.1116, the Dolby Atmos studio guide — with the signal to use.
  • Pink noise from this device at a chosen level, band (wideband, 500 Hz–2 kHz, 20–100 Hz for the LFE) and output channel.
  • Channel matching: the microphone stays at the listening position; each channel is measured for 6 seconds and compared with the first. A level difference needs no calibrated microphone; the absolute level is indicative.

Concert hall

  • Reference concert halls (Beranek) (checked, an answer in Room): the occupied mid RT (500 Hz / 1 kHz) against Beranek's chamber halls and the top symphony halls, with their initial time-delay gap for reference (not estimated here).
  • Clarity vs distance — Barron's revised theory (checked, in Speech & music): C80, C50, D50 and G at five distances from 20 to 100 % of the room length, the critical distance for an omni source, and the smallest differences you hear (ISO 3382-1, from published summaries). A diffuse-field estimate from the RT and the volume.
  • The STI estimate as for halls.

Cinema

In Room — X-curve:

  • X-curve target — SMPTE ST 202:2010 (checked): the target per ⅓ octave with its tolerance and the seat-count correction at 4 and 8 kHz (the audience count in the Room plan, interpolated between the table's 30–2 000 seats). ST 202 applies to rooms over 125 m³; below that the curve is shown for reference only.
  • Where the microphones go: seated ear height, at least 1.5 m from walls and 5 m from the screen speakers, enough positions for a spread under 3 dB.
  • Compare a measurement (in Measure › X-curve (RTA paste); Room › X-curve shows the result and has a Paste a measurement link): paste an RTA export ("frequency, dB" per line, wideband pink noise on one channel). RoomSense compares the shape only, lined up at 500 Hz–2 kHz; it needs a measurement microphone with its calibration file.

In System: the Speaker layout. In Show: the Reference listening level after SMPTE RP 200:2012 (checked) — 85 dBC per screen channel at −20 dBFS pink noise, each of two surround arrays 3 dB lower, the LFE +10 dB in-band on a real-time analyzer — with pink noise, and channel matching in Measure, as for studios.

Loudness targets

In the Reference sheet the loudness targets also list ATSC A/85 (−24 LKFS) and Netflix (−27 LKFS, dialogue-gated) — both from published summaries. Netflix gates on dialogue; the integrated value here gates on everything, so its difference is only a guide.

Was this page helpful?