Pick the feed
Schuko, CEE 16–125 A, a generator, or US Edison / 208 V — each with its per-phase breaker budget.
Free · A Squaresmile app
PowerSense turns your gear list into a phase plan: loads balanced across L1–L3, cable runs checked for gauge and voltage drop, distro headroom in plain numbers — and a printable sheet for the venue electrician.
How it works
Schuko, CEE 16–125 A, a generator, or US Edison / 208 V — each with its per-phase breaker budget.
From a preset library of consoles, amps, movers and more — or your own saved gear. Enter W, VA or plated amps.
Auto-balancing spreads the load largest-first; every row shows its phase. Pin the plan when you commit.
Cable runs get ampacity and voltage-drop verdicts. Export CSV or print the phase plan for the house electrician.
Features
Per-phase current bars against the breaker, amber at 80 %, red past the trip point — with a safety margin for inrush-heavy rigs.
Gauge, length and current per run: guideline ampacity plus voltage drop with 3 % / 5 % thresholds, in mm² or AWG.
One list per distro — FOH, stage, lighting, catering — and a site overview that adds them all up in W and kVA.
Motor hoists and 400 V racks split evenly across L1–L3, exactly like the copper does.
Save your racks once, add them with one tap — synced through your free account to every device.
The help explains the formulas and the habits pros live by: headroom, phase balance, drum unrolling, catering circuits, RCDs.
Who it's for
Make sure the amp racks and the lighting rig aren't fighting for the same phase before the first bass drop.
Plan movers, dimmed conventionals and hazers across phases, and know the cable run to the dimmer city is thick enough.
One list per circuit, a printable plan for the venue, and the catering kettle safely on its own breaker.
FAQ
No — it plans. The values are conservative guidelines for flexible rubber cable in free air, and the final distro is always signed off by a qualified electrician.
Generator feed presets budget per-phase current from the kVA rating and warn earlier — at 70 % continuous load, the way you should run a diesel.
Both. Europe mode is 230/400 V with mm² and meters; North America mode is 120/208 V with AWG and feet.
Plans live in your browser and sync to your Squaresmile account so they follow you across devices. No third parties involved.
Ready when you are
Create a free Squaresmile account and you're in — one login unlocks PowerSense and every other Squaresmile app.
The Squaresmile suite
Every browser tool below is free the moment you sign up. Create one account and the whole toolbox follows you from gig to gig — no installs, no app store.